bgpreport

Network · data from 2026-11-12

AS32 STANFORD - Stanford University

Registry name: STANFORD - Stanford University, US · not in PeeringDB

3IPv4 routes 0.0% RPKI valid · 66.7% with a route object
2IPv6 routes 0.0% RPKI valid · 100.0% with a route object
0RPKI invalid 0 origin · 0 maxLength
5No ROA 1 with no route object for this origin
0Low visibility seen by under 10% of full-table peers
0Route objects not announced registered with origin AS32, seen from no peer

Announced routes

Every prefix a peer of the route collectors sees with origin AS32, things to look at first. Visibility = full-table peers that see it, of 673 (IPv4) and 636 (IPv6) on 75 collectors. Also as routes.csv.

128.12.0.0/16 No ROA None 671 100% 69
204.63.224.0/21 No ROA Other IRR onlyRADB 671 100% 69
171.64.0.0/14 No ROA Other IRR onlyRADB 668 99% 69
2607:f6d0::/32 No ROA Other IRR onlyRADB 633 100% 69
2620:6c:40c0::/48 No ROA Other IRR onlyRADB 633 100% 69

AS-SET

AS32 isn't in PeeringDB, where networks name their AS-SET.

Fix list

The changes that would bring RPKI, the IRR and what's announced into line. Some are deliberate (a route object kept for a backup route, say); the network decides. All 10 are in fix.csv.

  • ROA: none5
  • Route object: none1
  • Route object: RIR4
ChangePrefix or setDetailFull-table peers
ROA: none128.12.0.0/16No ROA covers it. Add a ROA for AS32, maxLength 16.671 of 673
Route object: none128.12.0.0/16No route object for it. Add a route object with origin AS32 in the RIR database for the space.671 of 673
ROA: none204.63.224.0/21No ROA covers it. Add a ROA for AS32, maxLength 21.671 of 673
Route object: RIR204.63.224.0/21Route object only in RADB. Add it in the RIR database for the space.671 of 673
ROA: none171.64.0.0/14No ROA covers it. Add a ROA for AS32, maxLength 14.668 of 673
Route object: RIR171.64.0.0/14Route object only in RADB. Add it in the RIR database for the space.668 of 673
ROA: none2607:f6d0::/32No ROA covers it. Add a ROA for AS32, maxLength 32.633 of 636
Route object: RIR2607:f6d0::/32Route object only in RADB. Add it in the RIR database for the space.633 of 636
ROA: none2620:6c:40c0::/48No ROA covers it. Add a ROA for AS32, maxLength 48.633 of 636
Route object: RIR2620:6c:40c0::/48Route object only in RADB. Add it in the RIR database for the space.633 of 636

Route objects not announced

Every route object with origin AS32 is announced.

Routes: the 08:00 UTC snapshots of 2026-11-12 from 75 RIPE RIS and RouteViews collectors. RPKI: our rpki-client run before the snapshot. IRR: the day's dumps of the five RIR databases and RADB's mirrors. The LEVEL3 and IDNIC databases publish no dump and aren't read, so route objects only there count as none.